Expert Boiler Repairs by LHS Gas Safe Engineers in Chingford
- Jul 15
- 2 min read
Updated: 6 days ago
This week our Gas Safe engineer attended three different boiler jobs across Chingford. From boiler repairs to emergency breakdowns, here's what we found and how the issues were resolved.
Job 1 – Boiler Repair on Kings Road, Chingford
Customer called us to say their boilers hot water was running hot and cold on a Worcester Bosch Greenstar CDi 32kW combi boiler.
What we found
Boiler temperature running into the high 90's
Burner cutting out in hot water mode
Hot water temperatures max was reaching 35 degrees
The cause was due to a blocked plate heat exchanger, this was removed and cleaned, the boiler was also flushed to remove and further debris stuck in other components and prevent these from being transferred back into the cleaned plate heat exchanger. A system flush and a magnetic filter was recommended to prevent future contamination entering the boiler.

Tip for homeowners
Routine inspections of your boiler whether a service or maintenance visit will help identify potential leaks, missing components and water quality issues within the system preventing breakdowns and costly repairs to your boiler.
Job 2 – Ideal Boiler Repair on The Drive, Chingford
The homeowner reported no hot water and an F1 fault code on an Ideal Logic 24kW system boiler situated in kitchen cupboard.
After diagnosing the appliance we found low system pressure caused by a leaking thermostatic radiator valve upstairs in the master bedroom.
Work completed
Repaired leaking thermostatic radiator valve
Re-pressurised heating system
Reset boiler to clear fault code
Checked for further leaks within the boiler
Tested heating and hot water for correct operation
The boiler was back up and running within the 1st visit.
Job 3 – Vaillant Boiler Repair on The Ridgeway, Chingford
The customer called to state that their Vaillant Ecotec pro 28 combi boiler was leaking and required an emergency callout.
During inspection we noticed:
The plate heat exchanger was leaking from one side next to the pump
The auto air vent AAV was also leaking into the casing
Low pressure in the pressure gauge
The plate heat exchanger was removed and new seals were fitted, AAV was replaced and the boiler pressure was topped up to the recommended level, heating and hot water were tested for correct operation. A boiler service was also arranged which include a water qualtity test.

Common Boiler Problems We See Around Chingford
Many homes around Chingford have boilers between 8 and 15 years old, so we regularly attend:
Low boiler pressure
Leaking pressure relief valves
Faulty diverter valves
Failed expansion vessels
Ignition failures
Frozen condensate pipes in winter
Annual servicing for Viessmann, Worcester Bosch, Vaillant, Ideal and Baxi boilers
Boiler cycling and over heating
Need a Boiler Engineer in Chingford?
Whether you're in North Chingford, South Chingford, Chingford Green, Chingford Hatch, Chingford Mount, Friday Hill, Hale End, and Highams Park, we provide boiler installations boiler servicing, boiler repairs and landlord gas safety inspections carried out by our experienced Gas Safe engineers throughout the E4 area.
Call 0208 111 1230 today to arrange an appointment.